X

SM 531 AI 8xU/R/RTD/TC HF 16-bit SIEMENS 6ES7531-7PF00-0AB0

SIMATIC S7-1500 analog input module AI 8xU/R/RTD/TC HF, 16 bit resolution, up to 21 bit Resolution at RT and TC, accuracy 0.1%, 8 channels in groups of 1; common mode voltage: 30 V AC/60 V DC, Diagnostics; Hardware interrupts Scalable temperature measuring range, thermocouple type C, Calibrate in RUN; Delivery including infeed element, shield bracket and shield terminal: Front connector (screw terminals or push-in) to be ordered separately

6ES7531-7PF00-0AB0 là mô đun mở rộng tín hiệu ngõ vào tương tự cho PLC S7-1500 (CPU) do hãng SIEMENS phát triển & sản xuất với thương hiệu SIMATIC thuộc họ S7-1500. SM 531 AI 8xU/R/RTD/TC HF 16-bit SIEMENS 6ES7531-7PF00-0AB0 được SIEMENSIM.COM phát triển và phân phối rộng rãi trên thị trường Việt Nam. Nếu quý khách hàng đang có nhu cầu cần tư vấn hay mua 6ES7531-7PF00-0AB0 thì hãy liên hệ SIEMENS INDUSTRY MALL để được hỗ trợ một cách tận tâm, nhanh chóng và hiệu quả nhé.

Tóm tắt thông số kỹ thuật 6ES7531-7PF00-0AB0

Mã sản phẩm 6ES7531-7PF00-0AB0
Dòng sản phẩm SIMATIC S7-1500, SM 531
Hãng sản xuất SIEMENS
Số lượng đầu vào tương tự 8 AI U/R/RTD/TC HF, 16 bit
Nguồn cung cấp 24 V DC (20.4-28.8 V DC)
Kích thước (RxCxS) 35x147x129 mm
Trọng lượng 290 g

Chi tiết thông số kỹ thuật 6ES7531-7PF00-0AB0

Tải về datasheet (pdf): Tại đây!

General information
Product type designation AI 8xU/R/RTD/TC HF
HW functional status FS01
Firmware version V1.1.0
● FW update possible Yes
Product function
● I&M data Yes; I&M0 to I&M3
● Isochronous mode No
● Prioritized startup Yes
● Measuring range scalable Yes
● Scalable measured values No
● Adjustment of measuring range No
Engineering with
STEP 7 TIA Portal configurable/integrated from version V14 / –
● STEP 7 configurable/integrated from version V5.5 SP3 / –
● PROFIBUS from GSD version/GSD revision V1.0 / V5.1
● PROFINET from GSD version/GSD revision V2.3 / –
Operating mode
● Oversampling No
● MSI Yes
CiR – Configuration in RUN
Reparameterization possible in RUN Yes
Calibration possible in RUN Yes
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Input current
Current consumption, max. 55 mA; with 24 V DC supply
Power
Power available from the backplane bus 0.85 W
Power loss
Power loss, typ. 1.9 W
Analog inputs
Number of analog inputs 8; Plus one additional RTD (reference) channel
● For voltage measurement 8; Plus one additional RTD (reference) channel
● For resistance/resistance thermometer measurement 8; Plus one additional RTD (reference) channel
● For thermocouple measurement 8; Plus one additional RTD (reference) channel
permissible input voltage for voltage input (destruction limit), max. 20 V
Constant measurement current for resistance-type transmitter, typ. 150 Ohm, 300 Ohm, 600 Ohm, Cu10, Cu50, Cu100, Ni10, Ni100, Ni120, Ni200, Pt10, Pt50, Pt100, Pt200 climate: 1 mA; 6 kOhm, Ni500, Ni1000, LG-Ni1000, Pt200 standard, Pt500, Pt1000, PTC: 0.25 mA
Technical unit for temperature measurement adjustable Yes; °C/°F/K
Input ranges (rated values), voltages
● 0 to +5 V No
● 0 to +10 V No
● 1 V to 5 V No
● -1 V to +1 V Yes
— Input resistance (-1 V to +1 V) 10 MΩ
● -10 V to +10 V No
● -2.5 V to +2.5 V No
● -25 mV to +25 mV Yes
— Input resistance (-25 mV to +25 mV) 10 MΩ
● -250 mV to +250 mV Yes
— Input resistance (-250 mV to +250 mV) 10 MΩ
● -5 V to +5 V No
● -50 mV to +50 mV Yes
— Input resistance (-50 mV to +50 mV) 10 MΩ
● -500 mV to +500 mV Yes
— Input resistance (-500 mV to +500 mV) 10 MΩ
● -80 mV to +80 mV Yes
— Input resistance (-80 mV to +80 mV) 10 MΩ
Input ranges (rated values), currents
● 0 to 20 mA No
● -20 mA to +20 mA No
● 4 mA to 20 mA No
Input ranges (rated values), thermocouples
● Type B Yes
— Input resistance (Type B) 10 MΩ
● Type C Yes
— Input resistance (Type C) 10 MΩ
● Type E Yes
— Input resistance (Type E) 10 MΩ
● Type J Yes
— Input resistance (type J) 10 MΩ
● Type K Yes
— Input resistance (Type K) 10 MΩ
● Type L No
● Type N Yes
— Input resistance (Type N) 10 MΩ
● Type R Yes
— Input resistance (Type R) 10 MΩ
● Type S Yes
— Input resistance (Type S) 10 MΩ
● Type T Yes
— Input resistance (Type T) 10 MΩ
● Type TXK/TXK(L) to GOST Yes
— Input resistance (Type TXK/TXK(L) to GOST) 10 MΩ
Input ranges (rated values), resistance thermometer
● Cu 10 Yes; Standard/climate
— Input resistance (Cu 10) 10 MΩ
● Cu 10 according to GOST Yes; Standard/climate
— Input resistance (Cu 10 according to GOST) 10 MΩ
● Cu 50 Yes; Standard/climate
— Input resistance (Cu 50) 10 MΩ
● Cu 50 according to GOST Yes; Standard/climate
— Input resistance (Cu 50 according to GOST) 10 MΩ
● Cu 100 Yes; Standard/climate
— Input resistance (Cu 100) 10 MΩ
● Cu 100 according to GOST Yes; Standard/climate
— Input resistance (Cu 100 according to GOST) 10 MΩ
● Ni 10 Yes; Standard/climate
— Input resistance (Ni 10) 10 MΩ
● Ni 10 according to GOST Yes; Standard/climate
— Input resistance (Ni 10 according to GOST) 10 MΩ
● Ni 100 Yes; Standard/climate
— Input resistance (Ni 100) 10 MΩ
● Ni 100 according to GOST Yes; Standard/climate
— Input resistance (Ni 100 according to GOST) 10 MΩ
● Ni 1000 Yes; Standard/climate
— Input resistance (Ni 1000) 10 MΩ
● Ni 1000 according to GOST Yes; Standard/climate
— Input resistance (Ni 1000 according to GOST) 10 MΩ
● LG-Ni 1000 Yes; Standard/climate
— Input resistance (LG-Ni 1000) 10 MΩ
● Ni 120 Yes; Standard/climate
— Input resistance (Ni 120) 10 MΩ
● Ni 120 according to GOST Yes; Standard/climate
— Input resistance (Ni 120 according to GOST) 10 MΩ
● Ni 200 Yes; Standard/climate
— Input resistance (Ni 200) 10 MΩ
● Ni 200 according to GOST Yes; Standard/climate
— Input resistance (Ni 200 according to GOST) 10 MΩ
● Ni 500 Yes; Standard/climate
— Input resistance (Ni 500) 10 MΩ
● Ni 500 according to GOST Yes; Standard/climate
— Input resistance (Ni 500 according to GOST) 10 MΩ
● Pt 10 Yes; Standard/climate
— Input resistance (Pt 10) 10 MΩ
● Pt 10 according to GOST Yes; Standard/climate
— Input resistance (Pt 10 according to GOST) 10 MΩ
● Pt 50 Yes; Standard/climate
— Input resistance (Pt 50) 10 MΩ
● Pt 50 according to GOST Yes; Standard/climate
— Input resistance (Pt 50 according to GOST) 10 MΩ
● Pt 100 Yes; Standard/climate
— Input resistance (Pt 100) 10 MΩ
● Pt 100 according to GOST Yes; Standard/climate
— Input resistance (Pt 100 according to GOST) 10 MΩ
● Pt 1000 Yes; Standard/climate
— Input resistance (Pt 1000) 10 MΩ
● Pt 1000 according to GOST Yes; Standard/climate
— Input resistance (Pt 1000 according to GOST) 10 MΩ
● Pt 200 Yes; Standard/climate
— Input resistance (Pt 200) 10 MΩ
● Pt 200 according to GOST Yes; Standard/climate
— Input resistance (Pt 200 according to GOST) 10 MΩ
● Pt 500 Yes; Standard/climate
— Input resistance (Pt 500) 10 MΩ
● Pt 500 according to GOST Yes; Standard/climate
— Input resistance (Pt 500 according to GOST) 10 MΩ
Input ranges (rated values), resistors
● 0 to 150 ohms Yes
— Input resistance (0 to 150 ohms) 10 MΩ
● 0 to 300 ohms Yes
— Input resistance (0 to 300 ohms) 10 MΩ
● 0 to 600 ohms Yes
— Input resistance (0 to 600 ohms) 10 MΩ
● 0 to 3000 ohms No
● 0 to 6000 ohms Yes
— Input resistance (0 to 6000 ohms) 10 MΩ
● PTC Yes
— Input resistance (PTC) 10 MΩ
Thermocouple (TC)
Temperature compensation
— parameterizable Yes
— internal temperature compensation Yes
— external temperature compensation via RTD Yes
— Compensation for 0 °C reference point temperature Yes; fixed value can be set
— Reference channel of the module Yes; 9th channel that can be used as a genuine 9th RTD channel regardless of the parameterization of the other channels, or that can be used for compensation in the case of TC measurement
Cable length
● shielded, max. 800 m; at U; 200 m at R/RTD/TC
Analog value generation for the inputs
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max. 21 bit; For measuring mode RTC and TC when using the function “Scalable temperature measuring range” (32 bit REAL format); 16 bit for measuring mode R and U; 16 bit for all measuring modes when using the S7 format (16 bit INTEGER)
● Integration time, parameterizable Yes
● Integration time (ms) Fast mode: 2.5 / 16.67 / 20 / 100 ms, standard mode: 7.5 / 50 / 60 / 300 ms
● Basic conversion time, including integration time (ms) Fast mode: 4 / 18 / 22 / 102 ms; Standard mode: 9 / 52 / 62 / 302 ms
— additional conversion time for wire-break monitoring Thermocouples, 150 Ohm, 300 Ohm, 600 Ohm, Cu10, Cu50, Cu100, Ni10, Ni100, Ni120, Ni200, Pt10, Pt50, Pt100: 4 ms; 6 kOhm, Ni500, Ni1000, LG-Ni1000, Pt200, Pt500, Pt1000: 13 ms
● Interference voltage suppression for interference frequency f1 in Hz 400 / 60 / 50 / 10 Hz
● Basic execution time of the module (all channels released) Corresponds to the channel with the highest basic conversion time
Smoothing of measured values
● parameterizable Yes
● Step: None Yes
● Step: low Yes
● Step: Medium Yes
● Step: High Yes
Encoder
Connection of signal encoders
● for voltage measurement Yes
● for current measurement as 2-wire transducer No
● for current measurement as 4-wire transducer No
● for resistance measurement with two-wire connection Yes
● for resistance measurement with three-wire connection Yes; All measuring ranges except PTC; internal compensation of the cable resistances
● for resistance measurement with four-wire connection Yes; All measuring ranges except PTC
Errors/accuracies
Linearity error (relative to input range), (+/-) 0.02 %
Temperature error (relative to input range), (+/-) 0.005 %/K
Crosstalk between the inputs, max. -80 dB
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) 0.02 %
Temperature error of internal compensation ±1,5 °C
Operational error limit in overall temperature range
● Voltage, relative to input range, (+/-) 0.1 %
● Resistance, relative to input range, (+/-) 0.1 %
● Resistance thermometer, relative to input range, (+/-) Cuxxx Standard: ±0.5 K, Cuxxx Klima: ±0.5 K, Ptxxx Standard: ±1 K, Ptxxx Klima: ±0.5 K, Nixxx Standard: ±0.5 K, Nixxx Klima: ±0.3 K
● Thermocouple, relative to input range, (+/-) Type B: > 600 °C ±2 K, Type E: > -200 °C ±1 K, Type J: > -210 °C ±1 K, Type K: > -200 °C ±2 K, Type N: > -200 °C ±2 K, Type R: > 0 °C ±2 K, Type S: > 0 °C ±2 K, Type T: > -200 °C ±1 K, Type C: ±4 K, Type TXK/TXK(L): ±1 K
Basic error limit (operational limit at 25 °C)
● Voltage, relative to input range, (+/-) 0.05 %
● Resistance, relative to input range, (+/-) 0.05 %
● Resistance thermometer, relative to input range, (+/-) Cuxxx Standard: ±0.3 K, Cuxxx Klima: ±0.2 K, Ptxxx Standard: ±0.5 K, Ptxxx Klima: ±0.2 K, Nixxx Standard: ±0.3 K, Nixxx Klima: ±0.15 K
● Thermocouple, relative to input range, (+/-) Type B: > 600 °C ±1 K, Type E: > -200 °C ±0.5 K, Type J: > -210 °C ±0.5 K, Type K: > -200 °C ±1 K, Type N: > -200 °C ±1 K, Type R: > 0 °C ±1 K, Type S: > 0 °C ±1 K, Type T: > -200 °C ±0.5 K, Type C: ±2 K, Type TXK/TXK(L): ±0.5 K
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
● Series mode interference (peak value of interference < rated value of input range), min. 80 dB; in the Standard operating mode, 40 dB in the Fast operating mode
● Common mode voltage, max. 60 V DC/30 V AC
● Common mode interference, min. 80 dB
Interrupts/diagnostics/status information
Diagnostics function Yes
Alarms
● Diagnostic alarm Yes
● Limit value alarm Yes; two upper and two lower limit values in each case
Diagnoses
● Monitoring the supply voltage Yes
● Wire-break Yes; Only with TC, R, RTD
● Overflow/underflow Yes
Diagnostics indication LED
● RUN LED Yes; green LED
● ERROR LED Yes; red LED
● Monitoring of the supply voltage (PWR-LED) Yes; green LED
● Channel status display Yes; green LED
● for channel diagnostics Yes; red LED
● for module diagnostics Yes; red LED
Potential separation
Potential separation channels
● between the channels Yes
● between the channels, in groups of 1
● between the channels and backplane bus Yes
● between the channels and the power supply of the electronics Yes
Permissible potential difference
between different circuits 60 V DC/30 V AC; insulation rated for 120 V AC basic insulation: between the channels and the supply voltage L+; between the channels and the backplane bus; between the channels
Isolation
Isolation tested with 2 000 V DC between the channels and the supply voltage L+; 2 000 V DC between the channels and the backplane bus; 2 000 V DC between the channels; 707 V DC (type test) between the supply voltage L+ and the backplane bus
Standards, approvals, certificates
Suitable for applications according to AMS 2750 Yes; Declaration of Conformity, see online support entry 109757262
Suitable for applications according to CQI-9 Yes; Based on AMS 2750 E
Ambient conditions
Ambient temperature during operation
● horizontal installation, min. 0 °C
● horizontal installation, max. 60 °C
● vertical installation, min. 0 °C
● vertical installation, max. 40 °C
Dimensions
Width 35 mm
Height 147 mm
Depth 129 mm
Weights
Weight, approx. 290 g
Other
Note: for the R/RDT three-wire measurement, the conductor compensation is made alternating with the measurement; this then requires two module cycles for a measured value

Nhà phân phối & báo giá 6ES7531-7PF00-0AB0

Nếu quý khách hàng đang có nhu cầu cần tư vấn, báo giá hay mua 6ES7531-7PF00-0AB0 thì hãy liên hệ SIEMENS INDUSTRY MALL để được hỗ trợ một cách tận tâm, nhanh chóng và hiệu quả nhé.

Siemens: SIEMENSIM.COM là đơn vị cung cấp các giải pháp, dịch vụ và sản phẩm công nghiệp mang thương hiệu Siemens. Ngoài ra, chúng tôi còn được biết đến với nhiều tên gọi khác trên thị trường như: đại diện / đại lý / nhà cung cấp / nhà phân phối chính thức của Siemens tại Việt Nam.